Part Number Hot Search : 
TLC4066 9S12D VQFP1281 MMBZ5 14518B0 TA114 MKP1V120 CIMX2
Product Description
Full Text Search
 

To Download CCR-33K60-M Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ? 2013 teledyne relays (800) 284-7007 ? www.teledynecoax.com ccr-33k/cr-33k page 1 ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches electrical characteristics form factor spdt, break before make frequency range ccr-33k cr-33k dc?33.5 ghz dc?33.5 ghz characteristic impedance 50 ohms operate time 10 ms (max.) actuation voltage available 12 15 24 28 v actuation current, max. @ ambient 140 170 90 65 ma environmental and physical characteristics operating temperature commercial model, ccr-33k elite model, cr-33k ?40c to 65c ?55c to 85c vibration (mil-std-202 method 214, condition d, non-operating) 10 g?s rms shock (mil-std-202 method 213, condition d, non-operating) 500 g?s standard actuator life actuator life w/ additional features 5,000,000 cycles 1,000,000 cycles connector type 2.92mm humidity (moisture seal) available weight 1.65 oz. (46.78g) (max.) part numbering system connector k: 2.92mm female actuator voltage 6: 28 vdc latching 7: 15 vdc latching 8: 12 vdc latching 9: 24 vdc latching actuator type 0: standard contacts c: indicator contacts d: self cutoff only e: indicators and self cutoff **see parts list on pages 7-8 options t: ttl drivers with diodes d: transient suppression diodes r: positive + common n: narrow body m: moisture seal s: 9 pin d-sub connector actuator voltage ccr-33 k 6 c - t ** series connectors actuator type options for other options, contact factory. part number description ccr-33k commercial latching spdt, dc-33.5ghz cr-33k elite latching spdt, dc-33.5ghz the ccr-33k/cr-33k is a broadband, spdt, electromechanical, coaxial switch designed to switch a microwave signal from a common input to either of two outputs. the characteristic impedance is 50 ohms. the small switches incorporate 2.92mm connectors. the ccr-33k/cr-33k series switch is offered with a latching actuator. this design is compatible with the two most common mounting hole patterns. the ccr-33k/cr-33k series switch is interchangeable with a variety of switches. performance characteristics frequency dc?6 ghz 6?12 ghz 12?18 ghz 18?22 ghz 22-26.5 ghz 26.5-30 ghz 30-33.5 ghz insertion loss, db, max. 0.2 0.2 0.3 0.5 0.5 0.5 0.7 isolation, db, min. 90 80 75 75 70 65 50 vswr , max. 1.1:1 1.2:1 1.2:1 1.4:1 1.4:1 1.4:1 1.8:1
ccr-33k/cr-33k page 2 specifications are subject to change without notice ? 2013 teledyne coax switches ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches schematics and mechanical outline analog ttl indicators 9 pin d-sub pinout for latching spdt options pin no. basic indicators ttl indicators & ttl 11 1 22 2 3 c c common common 411 522 6vswvsw 7a a 8b b 9c c 1 6 ?- s option ? 9 - pin d - sub connector ( example : ccr -33 k 60- s ) truth table (with ttl option) logic input rf path indicator (if applicable) 12 in to 1 in to 2 ab 00 no change 10 on off c 0 01 off on 0 c 11 forbidden h = 1.30 max. std model h = 1.80 max. ttl model 2.92mm female connector h = 1.30 max. std model h = 1.80 max. ttl model 2.92mm female connector
? 2013 teledyne relays (800) 284-7007 ? www.teledynecoax.com ccr-33k/cr-33k page 3 ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches typical narrowband rf insertion loss performance curves -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 0123456 insertion loss (db) frequency (ghz) insertion loss ( dc-6 ghz ) -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 6789101112 insertion loss (db) frequency (ghz) insertion loss ( 6-12 ghz ) -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 12 13 14 15 16 17 18 insertion loss (db) frequency (ghz) insertion loss ( 12-18 ghz ) -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 18 19 20 21 22 insertion loss (db) frequency (ghz) insertion loss ( 18-22 ghz ) -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 22 23 24 25 26 insertion loss (db) frequency (ghz) insertion loss ( 22-26.5 ghz ) -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 26.5 27.5 28.5 29.5 insertion loss (db) frequency (ghz) insertion loss ( 26.5-30 ghz ) -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 30 31 32 33 insertion loss (db) frequency (ghz) insertion loss ( 30-33.5 ghz ) rf notes
ccr-33k/cr-33k page 4 specifications are subject to change without notice ? 2013 teledyne coax switches ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches typical narrowband rf isolation performance curves -140 -120 -100 -80 -60 -40 -20 0 0123456 isolation (db) frequency (ghz) isolation ( dc-6 ghz ) -140 -120 -100 -80 -60 -40 -20 0 6789101112 isolation (db) frequency (ghz) isolation ( 6-12 ghz ) -140 -120 -100 -80 -60 -40 -20 0 12 13 14 15 16 17 18 isolation (db) frequency (ghz) isolation ( 12-18 ghz ) -140 -120 -100 -80 -60 -40 -20 0 18 18.5 19 19.5 20 20.5 21 21.5 22 isolation (db) frequency (ghz) isolation ( 18-22 ghz ) -140 -120 -100 -80 -60 -40 -20 0 22 22.5 23 23.5 24 24.5 25 25.5 26 26.5 isolation (db) frequency (ghz) isolation ( 22-26.5 ghz ) -140 -120 -100 -80 -60 -40 -20 0 26.5 27 27.5 28 28.5 29 29.5 30 isolation (db) frequency (ghz) isolation ( 26.5-30 ghz ) -140 -120 -100 -80 -60 -40 -20 0 30 30.5 31 31.5 32 32.5 33 33.5 isolation (db) frequency (ghz) isolation ( 30-33.5 ghz ) rf notes
? 2013 teledyne relays (800) 284-7007 ? www.teledynecoax.com ccr-33k/cr-33k page 5 ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches typical narrowband rf vswr performance curves 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 0123456 vswr frequency (ghz) vswr ( dc-6 ghz ) 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 6789101112 vswr frequency (ghz) vswr ( 6-12 ghz ) 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 12 13 14 15 16 17 18 vswr frequency (ghz) vswr ( 12-18 ghz ) 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 18 18.5 19 19.5 20 20.5 21 21.5 22 vswr frequency (ghz) vswr ( 18-22 ghz ) 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 22 22.5 23 23.5 24 24.5 25 25.5 26 26.5 vswr frequency (ghz) vswr ( 22-26.5 ghz ) 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 26.5 27 27.5 28 28.5 29 29.5 30 vswr frequency (ghz) vswr ( 26.5-30 ghz ) 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 30 30.5 31 31.5 32 32.5 33 33.5 vswr frequency (ghz) vswr ( 30-33.5 ghz ) rf notes
ccr-33k/cr-33k page 6 specifications are subject to change without notice ? 2013 teledyne coax switches ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches actuator an actuator is the electromechanical mechanism that transfers the rf contacts from one position to another upon dc command. arc suppression diode a diode is connected in parallel with the coil. this diode limits the ?reverse emf spike? generated when the coil de- energizes to 0.7 volts. the diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. date code all switches are marked with either a unique serial number or a date code. date codes are in accordance with mil- std-1285 paragraph 5.2.5 and consist of four digits. the rst two digits de ne the year and the last two digits de ne the week of the year (yyww). thus, 1032 identi es switches that passed through nal inspection during the 32nd week of 2010. latching a latching switch remains in the selected position whether or not voltage is maintained. this can be accomplished with either a magnetic or mechanical latching mechanism. indicator indicators tell the system which position the switch is in. other names for indicators are telemetry contacts or tellback circuit. indicators are usually a set of internally mounted dc contacts linked to the actuator. they can be wired to digital input lines, status lights, or interlocks. unless otherwise speci ed, the maximum indicator contact rating is 30 vdc, 50 ma, or 1.5 watts into a resistive load. isolation isolation is the measure of the power level at the output connector of an unconnected rf channel as referenced to the power at the input connector. it is speci ed in db below the input power level. self-cutoff the self-cutoff option disables the actuator current on completion of actuation. either a series contact (linked to the actuator) or an ic driver circuit provides the current cutoff. this option results in minimum power consumption by the rf switch. cutthroat is another name used in the industry for this option. pulse latching is a term used to describe a switch without this feature. spdt switch a single-pole double-throw, bi-directional switch that can be used as having one input and two outputs or two inputs and one output. switching time switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch dc input and ending with the completion of the switch transfer, including contact bounce. it consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the rf contacts. ttl switch driver option as a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power schottky ttl circuits. performance parameters vs frequency generally speaking, the rf performance of coaxial switches is frequency dependent. with increasing frequency, vswr and insertion loss increase while isolation decreases. all data sheets specify these three parameters as ?worst case? at the highest operating frequency. if the switch is to be used over a narrow frequency band, better performance can be achieved. actuator current vs temperature the resistance of the actuator coil varies as a function of temperature. there is an inverse relationship between the operating temperature of the switch and the actuator drive current. for switches operating at 28 vdc, the approximate actuator drive current at temperature, t, can be calculated using the equation: magnetic sensitivity an electro-mechanical switch can be sensitive to ferrous materials and external magnetic elds. neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic elds should be limited to a ux density of less than 5 gauss. glossary i a [1 + .00385 (t-20)] where: i t = actuator current at temperature, t i a = room temperature actuator current C see data sheet t = temperature of interest in c i t = carrier frequency 1 carrier frequency 2 pim 3rd order frequency pim 5th order fre- quency 870 mhz 893 mhz 847 mhz 824 mhz 3rd order intermodulation 5th order intermodulation spdt ?91 dbm ?110 dbm ?134 dbc ?153 dbc special feature switching high-power or highly sensitive signals ensure the most linear response with the best galvanically matched contact system in the industry. extremely low passive intermodulation is standard on all of our switches.
? 2013 teledyne relays (800) 284-7007 ? www.teledynecoax.com ccr-33k/cr-33k page 7 ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches latching ccr-33k/cr-33k part number list * x = 6 (28vdc), 7 (15vdc), 8 (12vdc) and 9 (24vdc) p art n o .p art n o .p art n o .p art n o . 1 ccr-33kxc 43 ccr-33kxd-n 85 ccr-33kxe-tnm 127 cr-33kxc 2 ccr-33kxc-d 44 ccr-33kxd-n 86 ccr-33kxe-tnms 128 cr-33kxc-d 3 ccr-33kxc-dm 45 ccr-33kxd-nm 87 ccr-33kxe-tns 129 cr-33kxc-dm 4 ccr-33kxc-dms 46 ccr-33kxd-nms 88 ccr-33kx0 130 cr-33kxc-dms 5 ccr-33kxc-dn 47 ccr-33kxd-ns 89 ccr-33kx0-d 131 cr-33kxc-dn 6 ccr-33kxc-dnm 48 ccr-33kxd-r 90 ccr-33kx0-dm 132 cr-33kxc-dnm 7 ccr-33kxc-dnms 49 ccr-33kxd-rm 91 ccr-33kx0-dms 133 cr-33kxc-dnms 8 ccr-33kxc-dns 50 ccr-33kxd-rms 92 ccr-33kx0-dn 134 cr-33kxc-dns 9 ccr-33kxc-dr 51 ccr-33kxd-rn 93 ccr-33kx0-dnm 135 cr-33kxc-dr 10 ccr-33kxc-drm 52 ccr-33kxd-rnm 94 ccr-33kx0-dnms 136 cr-33kxc-drm 11 ccr-33kxc-drms 53 ccr-33kxd-rnms 95 ccr-33kx0-dns 137 cr-33kxc-drms 12 ccr-33kxc-drn 54 ccr-33kxd-rns 96 ccr-33kx0-dr 138 cr-33kxc-drn 13 ccr-33kxc-drnms 55 ccr-33kxd-rs 97 ccr-33kx0-drm 139 cr-33kxc-drnms 14 ccr-33kxc-drns 56 ccr-33kxd-s 98 ccr-33kx0-drms 140 cr-33kxc-drns 15 ccr-33kxc-drs 57 ccr-33kxd-t 99 ccr-33kx0-drn 141 cr-33kxc-drs 16 ccr-33kxc-ds 58 ccr-33kxd-tm 100 ccr-33kx0-drnms 142 cr-33kxc-ds 17 ccr-33kxc-m 59 ccr-33kxd-tms 101 ccr-33kx0-drns 143 cr-33kxc-m 18 ccr-33kxc-ms 60 ccr-33kxd-tn 102 ccr-33kx0-drs 144 cr-33kxc-ms 19 ccr-33kxc-n 61 ccr-33kxd-tnm 103 ccr-33kx0-ds 145 cr-33kxc-n 20 ccr-33kxc-nm 62 ccr-33kxd-tnms 104 ccr-33kx0-m 146 cr-33kxc-nm 21 ccr-33kxc-nms 63 ccr-33kxd-tns 105 ccr-33kx0-ms 147 cr-33kxc-nms 22 ccr-33kxc-ns 64 ccr-33kxe 106 ccr-33kx0-n 148 cr-33kxc-ns 23 ccr-33kxc-r 65 ccr-33kxe-m 107 ccr-33kx0-nm 149 cr-33kxc-r 24 ccr-33kxc-rm 66 ccr-33kxe-ms 108 ccr-33kx0-nms 150 cr-33kxc-rm 25 ccr-33kxc-rms 67 ccr-33kxe-n 109 ccr-33kx0-ns 151 cr-33kxc-rms 26 ccr-33kxc-rn 68 ccr-33kxe-n 110 ccr-33kx0-r 152 cr-33kxc-rn 27 ccr-33kxc-rnm 69 ccr-33kxe-nm 111 ccr-33kx0-rm 153 cr-33kxc-rnm 28 ccr-33kxc-rnms 70 ccr-33kxe-nms 112 ccr-33kx0-rms 154 cr-33kxc-rnms 29 ccr-33kxc-rns 71 ccr-33kxe-ns 113 ccr-33kx0-rn 155 cr-33kxc-rns 30 ccr-33kxc-rs 72 ccr-33kxe-r 114 ccr-33kx0-rnm 156 cr-33kxc-rs 31 ccr-33kxc-s 73 ccr-33kxe-rm 115 ccr-33kx0-rnms 157 cr-33kxc-s 32 ccr-33kxc-t 74 ccr-33kxe-rms 116 ccr-33kx0-rns 158 cr-33kxc-t 33 ccr-33kxc-tm 75 ccr-33kxe-rn 117 ccr-33kx0-rs 159 cr-33kxc-tm 34 ccr-33kxc-tms 76 ccr-33kxe-rnm 118 ccr-33kx0-s 160 cr-33kxc-tms 35 ccr-33kxc-tn 77 ccr-33kxe-rnms 119 ccr-33kx0-t 161 cr-33kx0-t 36 ccr-33kxc-tnm 78 ccr-33kxe-rns 120 ccr-33kx0-tm 162 cr-33kx0-tm 37 ccr-33kxc-tnms 79 ccr-33kxe-rs 121 ccr-33kx0-tms 163 cr-33kx0-tms 38 ccr-33kxc-tns 80 ccr-33kxe-s 122 ccr-33kx0-tn 164 cr-33kx0-tn 39 ccr-33kxc-ts 81 ccr-33kxe-t 123 ccr-33kx0-tnm 165 cr-33kx0-tnm 40 ccr-33kxd 82 ccr-33kxe-tm 124 ccr-33kx0-tnms 166 cr-33kx0-tnms 41 ccr-33kxd-m 83 ccr-33kxe-tms 125 ccr-33kx0-tns 167 cr-33kx0-tns 42 ccr-33kxd-ms 84 ccr-33kxe-tn 126 ccr-33kx0-ts 168 cr-33kx0-ts
ccr-33k/cr-33k page 8 specifications are subject to change without notice ? 2013 teledyne coax switches ccr-33k\cr-33k\082013\q3 series ccr-33k/cr-33k miniature dc?33.5 ghz latching spdt coaxial switch coax switches latching ccr-33k/cr-33k part number list * x = 6 (28vdc), 7 (15vdc), 8 (12vdc) and 9 (24vdc) p art n o .p art n o . 169 cr-33kxc-tn 211 cr-33kxe-rnms 170 cr-33kxc-tnm 212 cr-33kxe-rns 171 cr-33kxc-tnms 213 cr-33kxe-rs 172 cr-33kxc-tns 214 cr-33kxe-s 173 cr-33kxc-ts 215 cr-33kxe-t 174 cr-33kxd 216 cr-33kxe-tm 175 cr-33kxd-m 217 cr-33kxe-tms 176 cr-33kxd-ms 218 cr-33kxe-tn 177 cr-33kxd-n 219 cr-33kxe-tnm 178 cr-33kxd-n 220 cr-33kxe-tnms 179 cr-33kxd-nm 221 cr-33kxe-tns 180 cr-33kxd-nms 222 cr-33kx0 181 cr-33kxd-ns 223 cr-33kx0-d 182 cr-33kxd-r 224 cr-33kx0-dm 183 cr-33kxd-rm 225 cr-33kx0-dms 184 cr-33kxd-rms 226 cr-33kx0-dn 185 cr-33kxd-rn 227 cr-33kx0-dnm 186 cr-33kxd-rnm 228 cr-33kx0-dnms 187 cr-33kxd-rnms 229 cr-33kx0-dns 188 cr-33kxd-rns 230 cr-33kx0-dr 189 cr-33kxd-rs 231 cr-33kx0-drm 190 cr-33kxd-s 232 cr-33kx0-drms 191 cr-33kxd-t 233 cr-33kx0-drn 192 cr-33kxd-tm 234 cr-33kx0-drnms 193 cr-33kxd-tms 235 cr-33kx0-drns 194 cr-33kxd-tn 236 cr-33kx0-drs 195 cr-33kxd-tnm 237 cr-33kx0-ds 196 cr-33kxd-tnms 238 cr-33kx0-m 197 cr-33kxd-tns 239 cr-33kx0-ms 198 cr-33kxe 240 cr-33kx0-n 199 cr-33kxe-m 241 cr-33kx0-nm 200 cr-33kxe-ms 242 cr-33kx0-nms 201 cr-33kxe-n 243 cr-33kx0-ns 202 cr-33kxe-n 244 cr-33kx0-r 203 cr-33kxe-nm 245 cr-33kx0-rm 204 cr-33kxe-nms 246 cr-33kx0-rms 205 cr-33kxe-ns 247 cr-33kx0-rn 206 cr-33kxe-r 248 cr-33kx0-rnm 207 cr-33kxe-rm 249 cr-33kx0-rnms 208 cr-33kxe-rms 250 cr-33kx0-rns 209 cr-33kxe-rn 251 cr-33kx0-rs 210 cr-33kxe-rnm 252 cr-33kx0-s


▲Up To Search▲   

 